Measuring range : 0.5 - 125 ppm , Scale range : 0.5 - 30 ppm
Other substances measurable with this detector tube : Iodine
10 results found for 'Nitrogen dioxide'
Displaying 1~10 of 10 products
-
Short-term measurement detector tubes
-
Long-term measurement detector tubes
Measuring range : 0.1 - 30 ppm , Scale range : 1 - 30 ppm・hr
-
Long-term measurement detector tubes
Measuring range : 0.01 - 3.0 ppm , Scale range : (0.1) - 3.0 ppm・hr
-
Detector tubes for Automatic air sampling pump
Measuring range : 0.02 - 0.20 ppm , Scale range : 0.02 - 0.20 ppm
-
Short-term measurement detector tubes
NO & NO2(Separate quantification)10
Nitrogen oxide
Measuring range : 2.5 - 200 ppm , Scale range : 5 - 200 ppm
Nitrogen dioxide
Measuring range : 2.5 - 200 ppm , Scale range : 2.5 - 200 ppm -
PYROTEC detector tubes
Measuring range : 0.5 - 30 ppm , Scale range : 0.5 - 30 ppm
Other substances measurable with this detector tube : Nitrogen dioxide,Acetonitrile,Nitroethane,1-Nitropropane,2-Nitropropane,Nitromethane -
Short-term measurement detector tubes
Measuring range : 1 - 80 ppm , Scale range : 2 - 40 ppm
Other substances measurable with this detector tube : Hydrogen chloride,Chlorine,Nitric acid,Nitrogen dioxide,Sulphur dioxide,Iodine -
Gas sensors
Controlled potential electrolysis sensor
From the mid-1960s, controlled potential electrolysis type sensors have attracted much attention as a means for sensing and measuring air pollutants such as sulphur dioxide and nitrogen oxide right at the source where they are generated and they are increasingly being used in such contents. In the latter half of the 1970s, they came to be more widely accepted as carbon monoxide or hydrogen sulphide measuring instruments alongside other combustion type or galvanic sensors, not only for flue gas monitoring or occupational hygiene and safety applications.
-
Calibration gas generation system
Generating calibration gas with a permeation tube
Permeation tube nitrogen dioxideP-9-1
Concentration range 0.05 - 3.99 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled. -
Calibration gas generation system
Generating calibration gas with a permeation tube
Permeation tube nitrogen dioxideP-9-H
Concentration range 1.8 - 133 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.