Controlled potential electrolysis sensor
Hydrogen sulphide sensorH2S-50EE
30 x 30 x 26 25g : HS-5C
GASTEC CORPORATION - For all types of gas and vapour
Controlled potential electrolysis sensor
Hydrogen sulphide sensorH2S-50EE
30 x 30 x 26 25g : HS-5C
Catalytic combustion sensors
33 x 30 x 36 30g : MA-2510 / GOM-3A / GOMHC-3A
Catalytic combustion sensors
33 x 30 x 36 30g : MA-0510 / GOM-3AL
Non-Dispersive Infrared Absorption Sensors
30 x 30 x 100 25g : CMCD-200
Even calibration gas of very low concentrations can be continuously generated.
The Permeater is a gas generator for calibration purposes that utilises permeation and diffusion tubes to generate the calibration gas.
*PD-1B has been discontinued.
Even calibration gas of very low concentrations can be continuously generated.
*The products may not be sold depending on countries and regions.
Generating calibration gas with a permeation tube
Permeation tube acetaldehydeP-92-1
Concentration range 0.1 - 5.2 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Concentration range 0.2 - 17.9 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Concentration range 0.3 - 40.8ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Permeation tube 1, 3-butadieneP-174-H
Concentration range 0.7 - 31ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Concentration range 0.016 - 2.52 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Concentration range 0.04 - 4.30 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Concentration range 0.15 - 16.4ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Concentration range 0.5 - 53.1 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Permeation tube dimethyl disulphideP-73-H
Concentration range 0.003 - 0.45 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Permeation tube dimethyl sulphideP-74-H
Concentration range 0.04 - 6.3 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Permeation tube dimethylamineP-181-H
Concentration range 0.2 - 10.3 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Permeation tube ethyl mercaptanP-72-H
Concentration range 0.04 - 1.87 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Permeation tube ethylene oxideP-163-H
Concentration range 0.5 - 23 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.
Generating calibration gas with a permeation tube
Permeation tube formaldehydeP-91-H-5
Concentration range 0.0049 - 0.24 ppm
*As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.