Compact, lightweight, and reliable automatic air sampling pump for GASTEC detector tubes and sorbent tubes.
- Flow range 50 - 500mL/min
- 10 - 500mL/min is available when volume mode (When set to 10 - 49 mL/min, the intermittent operation is performed at 50mL/min)
- Fixed flow function automatically regulates load changes
- Flow rate, sampling time, and integrated volume are displayed on the same screen simultaneously
- Quiet operation with low noise
- Automatic start enables sampling to begin after a preset time
- 5 sampling settings can be saved with the program mode
- Real-time flow volume and integrated flow volume are automatically corrected to the values for 20ºC(68ºF) or 25ºC(77ºF)



Specifications
Sampling mode | Timer Mode:Air pump automatically stops at set time Settable time: 1 minute to 30 hours Volume Mode:Air pump automatically stops at set volume Settable integrated volume: 0.010 to 900L |
---|---|
Settable instantaneous flow rate | Timer Mode:50-500mL/min Volume Mode:10-500mL/min (When set to 10-49 mL/min, the intermittent operation is performed at 50mL/min) |
Constant flow rate operating range |
10-49mL/min:0.0-5.0kPa 300mL/min:0.0-23.0kPa 50mL/min:0.0-40.0kPa 400mL/min:0.0-16.0kPa 100mL/min:0.0-37.0kPa 500mL/min:0.0-10.0kPa 200mL/min:0.0-30.0kPa |
Display | Liquid crystal digital display (with backlight), Display range:0-600mL/min |
Structure and function | Constant flow rate function (built-in set flow rate holding circuit), Autostart function (autostart after set standby time in standby mode), Diaphragm type air pump, Program Mode (5 sampling settings) |
Accuracy of instantaneous flow measurement | Instantaneous flow rate: 50-500 mL/min ±5% |
Accuracy of integrated flow Measurement |
[When set flow rate: 50 to 500mL/min] ± 5%. <Volume Mode only> [When set flow rate: 10 to 49mL/min] ±(2.5×sampling time [min]) mL. |
Operating temperature range | 0-40℃ |
Operating humidity range | 10-90% RH (non-condensing) |
Power supply | 2 AA alkaline batteries (standard accessories, commercially available) 2 AA nickel-metal hydride batteries (commercially available) |
Continuous operation time | 2 AA alkaline batteries (Standard Accessories): 20 hours (Set flow rate: 200 mL/min, suction pressure: 2kPa or less, ambient temperature: 25°C) |
Dimensions and weight | 80(W) ×40(D)×126(H) mm 280g (including batteries) |
Standard accessories | 2 AA alkaline batteries , detector tube adaptor, tube tip holder, dust filter (5 pcs), instruction manual, warranty certificate, inspection certificate |
Directives and regulations | 2014/30/EU(EMC), 2011/65/EU,(EU)2015/863(RoHS), (EU)2023/1542(BATTERY) |
EMC harmonised standards | EN 61326-1:2013 |
RoHS designated standards | EN IEC63000:2018 |
Intermittent Operation
When the instantaneous flow rate is set to 10 - 49mL/min in the Volume Mode, the intermittent operation is performed by sampling at an instantaneous flow rate of 50mL/min.
When the Volume Mode is selected and the flow rate is set to 10 mL/min and the set volume is 0.1L, after the sampling is started, the pump will pause for about 48 seconds after about 12 seconds of sampling at a flow rate of 50mL/min (samples until the sampled volume per minute reaches 10mL, then pauses). Sampling at a flow rate of 50 mL/min for about 12 seconds and pausing for about 48 seconds are repeated until the set volume of 0.1 L is reached, taking about 10 minutes.

Sorbent tubes
Product name/code | Layer | Filling quantity | Dimensions(mm) | Tubes/box | Shelf life (months) | |
---|---|---|---|---|---|---|
Activated charcoal tube | 251S-20 | 2 | 100/50 | 5.6×100 | 20 | 60 |
251S2-20 | 1 | 150 | 5.6×100 | 20 | 60 | |
Activated charcoal tube (Bead-shaped) | 258-20 | 2 | 100/50 | 5.6×100 | 20 | 60 |
258A-20 | 2 | 400/200 | 7.0×105 | 20 | 60 | |
258S2-20 | 1 | 150 | 5.6×100 | 20 | 60 | |
Silica-gel tube | 252S-20 | 2 | 400/200 | 7.0×105 | 20 | 60 |
252S2-20 | 1 | 600 | 7.0×105 | 20 | 60 | |
252S3-20 | 2 | 150/75 | 5.6×100 | 20 | 60 | |
252S4-20 | 1 | 300 | 5.6×100 | 20 | 60 |
Detector tube
Substance to be measured | Tube no. & name | Measuring range (ppm) |
Scale range (ppm) |
No. of tests per box |
Detector tube type | Notes | |
---|---|---|---|---|---|---|---|
Acetone | 151TP | Acetone | 25-800 | (25)-800 | 10 | Automatic air sampling pump | |
Acrylonitrile | 191TP | Acrylonitrile | 0.2-12.6 | 0.2-3.0 | 5 | Automatic air sampling pump | |
Ammonia | 3S | Ammonia | 0.5-5 | 0.5-5 | 10 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Benzene | 121TP | Benzene | 0.1-14.5 | 0.1-5 | 5 | Automatic air sampling pump | |
121P | Benzene | 250-3000µg/m3 | (250)-3000µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants | |
Carbon disulphide | 13TP | Carbon disulphide | 0.05-2.4 | (0.05)-1.00 | 5 | Automatic air sampling pump | |
Chlorine | 8TP | Chlorine | 0.05-0.6 | 0.05-0.6 | 10 | Automatic air sampling pump | Residential environment |
p-Dichlorobenzene | 127P | p-Dichlorobenzene | 100-3000µg/m3 | 100-3000µg/m3 | 5 | Automatic air sampling pump | Residential environment |
N,N-Dimethylacetamide | 183TP | N,N-Dimethylformamide | 3.0-57.5 | 10 | Automatic air sampling pump | ||
N,N-Dimethylformamide | 183TP | N,N-Dimethylformamide | 0.5-30 | (0.5)-15 | 10 | Automatic air sampling pump | |
Ethyl benzene | 122P | Toluene | 110-2750µg/m3 | 5 | Automatic air sampling pump | Residential environment | |
Ethylene oxide | 163TPM | Ethylene oxide | 1-50 | 1-50 | 5 | Automatic air sampling pump | |
163TP | Ethylene oxide | 0.1-5 | 0.1-5 | 5 | Automatic air sampling pump | ||
Formaldehyde | 91P | Formaldehyde | 0.02-1.44 | 0.02-0.4 | 10 | Automatic air sampling pump | Residential environment Indoor environment |
91PL | Formaldehyde | 0.01-0.80 | (0.01)-0.20 | 10 | Automatic air sampling pump | Residential environment Indoor environment | |
91TP | Formaldehyde | 0.01-1.75 | 0.01-0.50 | 10 | Automatic air sampling pump | ||
Hexane | 102TP | Hexane | 2-80 | 2-80 | 10 | Automatic air sampling pump | |
Hydrogen cyanide | 12TP | Hydrogen cyanide | 0.3-9.0 | 0.3-4.5 | 10 | Automatic air sampling pump | |
Hydrogen fluoride | 17TP | Hydrogen fluoride | 0.05-9.0 | 0.05-3.0 | 10 | Automatic air sampling pump | |
Hydrogen sulphide | 4S | Hydrogen sulphide | 10-200ppb | 10-200ppb | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
4TP | Hydrogen sulphide | 0.1-2.88 | 0.1-1.6 | 10 | Automatic air sampling pump | ||
Isopropyl alcohol | 113TP | Isopropyl alcohol | 20-400 | 20-200 | 10 | Automatic air sampling pump | |
Methanol | 111TP | Methanol | 20-300 | 20-300 | 10 | Automatic air sampling pump | |
Methyl ethyl ketone | 152TP | Methyl ethyl ketone | 20-300 | 20-300 | 10 | Automatic air sampling pump | |
Nitrogen dioxide | 9P | Nitrogen dioxide | 0.02-0.20 | 0.02-0.20 | 10 | Automatic air sampling pump | Residential environment |
Styrene | 124S | Styrene | 0.2-4.0 | 0.2-4.0 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Tetrachloroethylene | 133TP | Tetrachloroethylene | 2.5-84 | 2.5-40 | 5 | Automatic air sampling pump | |
133P | Tetrachloroethylene | 20-720µg/m3 | 20-300µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants | |
Toluene | 122TP | Toluene | 2-80 | 2-80 | 5 | Automatic air sampling pump | |
122P | Toluene | 100-7000µg/m3 | 100-2500µg/m3 | 5 | Automatic air sampling pump | Residential environment | |
Trichloroethylene | 132TP | Trichloroethylene | 1-33 | 1-15 | 5 | Automatic air sampling pump | |
132P | Trichloroethylene | 20-1200µg/m3 | 20-500µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants | |
Vinyl chloride | 131TP | Vinyl chloride | 0.2-9.6 | 0.2-3.0 | 10 | Automatic air sampling pump | |
131P | Vinyl chloride | 50-1500µg/m3 | 50-1500µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants | |
Xylene | 123TP | Xylene | 2-80 | 2-80 | 5 | Automatic air sampling pump | |
122P | Toluene | 540-13500µg/m3 | 5 | Automatic air sampling pump | Residential environment |
How to use
- 1.
- Break tips off the detector tube using the tube tip holder.

- 2.
- Insert the detector tube to the inlet of the rubber tube holder.
Put the power switch to ON. Adjust the flow rate, confirm that the timer of the air sampling pump is set, then push the start button.

- 3.
- After sampling, remove the detector tube from the rubber tube holder and read the concentration of the tube.

Options

Gas sampling pump tripod stand GSP-TRIPOD
Mount GSP-501FT to use at the desired height.

Belt loop pump holder GSP500FT-30
Case for personal exposure measurement

Tube holder for personal exposure measurement

Protective cover for detector tube GSP300-14
Enables the detector tube to be securely set up for measuring and helps to avoid possible injury to the user as well as damage to the detector tube itself.

Reusable rubber caps can be attached to the broken tip of the detector tubes as an extra precautionary safety measure. One (1) package contains 20 caps.

2 pumps can be mounted on the same tripod