Flow volume of 50-1000mL/min can be set.
- Real-time flow volume and integrated flow volume are automatically corrected to the values for 20ºC(68ºF) or 25ºC(77ºF)
- Optimal suction even at maximum load



Specifications
Integrated flow rate | 50 - 1000mL/min |
---|---|
Real-time flow rate Parametres | 50mL/min : 0.0 - 37.0 kPa , 100mL/min : 0.0 - 36.0 kPa 300mL/min : 0.0 - 33.0 kPa , 500mL/min : 0.0 - 29.0 kPa 700mL/min : 0.0 - 24.0 kPa , 1000mL/min : 0.0 - 16.0 kPa |
Operating Temperature / Humidity range | Temperature : 0 - 40 ºC(32- 104 ºF) Relative humidity : 10 - 90 %RH(no condensation) |
Dimensions | 150(W) x 75(D) x 100(H) mm |
Weight | 500g (including batteries) |
Detector tube
Substance to be measured | Tube no. & name | Measuring range (ppm) |
Scale range (ppm) |
No. of tests per box |
Detector tube type | Notes | |
---|---|---|---|---|---|---|---|
Ammonia | 3S | Ammonia | 0.5-5 | 0.5-5 | 10 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Benzene | 121P | Benzene | 250-3000µg/m3 | (250)-3000µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Hydrogen sulphide | 4S | Hydrogen sulphide | 10-200ppb | 10-200ppb | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Styrene | 124S | Styrene | 0.2-4.0 | 0.2-4.0 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Tetrachloroethylene | 133P | Tetrachloroethylene | 20-720µg/m3 | 20-300µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Trichloroethylene | 132P | Trichloroethylene | 20-1200µg/m3 | 20-500µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Vinyl chloride | 131P | Vinyl chloride | 50-1500µg/m3 | 50-1500µg/m3 | 5 | Automatic air sampling pump | Sampling of hazardous air pollutants |
Options

The air sampling is used to collect samples of harmful aldehydes, by connecting the ozone scrubber to the front stage and two DNPH collection tubes to the rear stage.
However, excessive moisture due to rain may interfere with collection by causing condensation in the collection tube.
The GTH-1 prevent voltage(plus 10ºC reliable to the outside air)thus enabling reliable samoling on a 24-hour basis.
In addition, the GHT-1 has a compact and lightweight desugn so it can be attached to the GSP series.

Holder for Various Collection Tubes GSP-SH
The collection tube is set into the holder.

GSP-SH tripod adapter GSPSH-71
Necessary when installing the collection tube holder on a tripod.

Detector tube adapter GSP300-13
Installed when mounting the detector tube and the collection tube on the GSP-400FT automatic gas sampling unit.