GASTEC CORPORATION - For all types of gas and vapour

Automatic Air Sampling PumpGSP-400FT

Flow volume of 50-1000mL/min can be set.

  • Real-time flow volume and integrated flow volume are automatically corrected to the values for 20ºC(68ºF) or 25ºC(77ºF)
  • Optimal suction even at maximum load
Automatic Air Sampling Pump GSP-400FT
*The products may not be sold depending on countries and regions. 

Specifications

Integrated flow rate 50 - 1000mL/min
Real-time flow rate Parametres 50mL/min : 0.0 - 37.0 kPa , 100mL/min : 0.0 - 36.0 kPa
300mL/min : 0.0 - 33.0 kPa , 500mL/min : 0.0 - 29.0 kPa
700mL/min : 0.0 - 24.0 kPa , 1000mL/min : 0.0 - 16.0 kPa
Operating Temperature / Humidity range Temperature : 0 - 40 ºC(32- 104 ºF)
Relative humidity : 10 - 90 %RH(no condensation)
Dimensions 150(W) x 75(D) x 100(H) mm
Weight 500g (including batteries)

Detector tube

Substance to be measured Tube no. & name Measuring range
(ppm)
Scale range
(ppm)
No. of
tests
per box
Detector tube type Notes
Ammonia 3S Ammonia 0.5-5 0.5-5 10 Automatic air sampling pump Sampling of hazardous air pollutants
Benzene 121P Benzene 250-3000µg/m3 (250)-3000µg/m3 5 Automatic air sampling pump Sampling of hazardous air pollutants
Hydrogen sulphide 4S Hydrogen sulphide 10-200ppb 10-200ppb 5 Automatic air sampling pump Sampling of hazardous air pollutants
Styrene 124S Styrene 0.2-4.0 0.2-4.0 5 Automatic air sampling pump Sampling of hazardous air pollutants
Tetrachloroethylene 133P Tetrachloroethylene 20-720µg/m3 20-300µg/m3 5 Automatic air sampling pump Sampling of hazardous air pollutants
Trichloroethylene 132P Trichloroethylene 20-1200µg/m3 20-500µg/m3 5 Automatic air sampling pump Sampling of hazardous air pollutants
Vinyl chloride 131P Vinyl chloride 50-1500µg/m3 50-1500µg/m3 5 Automatic air sampling pump Sampling of hazardous air pollutants

Options

The air sampling is used to collect samples of harmful aldehydes, by connecting the ozone scrubber to the front stage and two DNPH collection tubes to the rear stage.
However, excessive moisture due to rain may interfere with collection by causing condensation in the collection tube.
The GTH-1 prevent voltage(plus 10ºC reliable to the outside air)thus enabling reliable samoling on a 24-hour basis.
In addition, the GHT-1 has a compact and lightweight desugn so it can be attached to the GSP series.

The collection tube is set into the holder.

Necessary when installing the collection tube holder on a tripod.

Installed when mounting the detector tube and the collection tube on the GSP-400FT automatic gas sampling unit.