GASTEC CORPORATION - For all types of gas and vapour

Pyrotec pyrolyzer840

GASTEC developed the Pyrotec Pyrolyzer system to enable precise and easy detection of fluorochlorocarbon gases. It converts fluorochlorocarbon gases or halogenated hydrocarbons (using a process known as thermal cracking) into an easily detectable/measurable gas.

Pyrotec pyrolyzer 840

Specifications

Operating principle pyrolysis
Power source 4 AA batteries
Continuous operation time approx 2 hrs
Filament life Freon 113 1,000 measurements at 6,000 ppm
Standard operating temperature range 0 - 40ºC (32 - 104ºF)
Dimensions φ68 x 150
weight 290g

Detector tube

Pyrotec pyrolyzer: Table of measurable (Target) gases

Substance to be measured Tube no. & name Measuring range
(ppm)
Scale range
(ppm)
No. of
tests
per box
Detector tube type Notes
Acetonitrile 52 Nitro compounds 3-180 10 PYROTEC Use Pyrotec Pyrolyzer No. 840
Chlorodifluoromethane 51H Fluorochlorocarbons 1000-24000 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 25-1000 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 2.5-135 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
2-Chloro-1,1,1,2- tetrafluoroethane 51 Fluorochlorocarbons 45-1800 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Dichlorodifluoromethane 51H Fluorochlorocarbons 325-7800 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 11-440 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 1.8-97.2 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
1,1-Dichloro-1-fluoroethane 51 Fluorochlorocarbons 10-1000 10-400 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 1.1-22 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Dichloropentafluoropropane 51 Fluorochlorocarbons 20-800 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 1.4-28 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
1,2-Dichloro-1,1,2,2- tetrafluoroethane 51H Fluorochlorocarbons 475-11400 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 20-800 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 1.8-97.2 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
2,2-Dichloro-1,1,1- trifluoroethane 51 Fluorochlorocarbons 14-1600 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 1.4-28 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Dimethyl disulphide 53 Dimethyl sulphide 0.3-6 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Dimethyl sulphide 53 Dimethyl sulphide 0.15-10 (0.5)-10 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Enflurane 51 Fluorochlorocarbons 110-1230 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 25-145 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Halothane 51H Fluorochlorocarbons 800-6400 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 24-960 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 3-60 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Methyl chloride 51 Fluorochlorocarbons 12-480 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 1.6-86.4 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Methylene chloride 51L Fluorochlorocarbons 1-54 1-20 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Nitroethane 52 Nitro compounds 4-240 10 PYROTEC Use Pyrotec Pyrolyzer No. 840
Nitrogen dioxide 52 Nitro compounds 0.5-30 0.5-30 10 PYROTEC Use Pyrotec Pyrolyzer No. 840
Nitromethane 52 Nitro compounds 5-300 10 PYROTEC Use Pyrotec Pyrolyzer No. 840
1-Nitropropane 52 Nitro compounds 4.2-252 10 PYROTEC Use Pyrotec Pyrolyzer No. 840
2-Nitropropane 52 Nitro compounds 3.7-222 10 PYROTEC Use Pyrotec Pyrolyzer No. 840
1,1,2,2-Tetrachloro-1,2- difluoroethane 51H Fluorochlorocarbons 125-3000 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 7-280 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 1-54 1-20 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
Trichlorofluoromethane 51H Fluorochlorocarbons 275-6600 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 8-320 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 0.8-43.2 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
1,1,1-Trichloro-2,2,2- trifluoroethane 51H Fluorochlorocarbons 200-4800 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 10-400 10-400 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51L Fluorochlorocarbons 0.8-43.2 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
1,1,2-Trichloro-1,2,2- trifluoroethane 51H Fluorochlorocarbons 250-6000 250-2000 5 PYROTEC Use Pyrotec Pyrolyzer No. 840
51 Fluorochlorocarbons 10-400 10-400 5 PYROTEC Use Pyrotec Pyrolyzer No. 840